QA3000 Vehicle Gas Alarm System Operation Manual

 

Adopting high quality gas sensor and advanced electronical technology, QA3000 vehicle gas alarm system has the advantages of excellent performance, lower consumption, easy operation and maintenance. It is widely used in gas powered taxi and bus, so as to avoid fire emergency or explosion due to gas leakage.

Technical Data:

Model

QA3000

Gas sensor

Semiconductor

Detecting gas

Natural gas, LPG

Working voltage

DC12V+/-1V

Working condition

Temperature: -40oC-70 oC      Humidity: <=95%RH

Storage temperature

-40 oC-70 o

Pressure limit

86kPa-106 kPa

Consumption

Alarming status <1W   Non-alarming status <1.5 W

Response time

<=30s   Auto resume

Gas sampling

Natural diffusion

Detection range

0-100%LEL

Preset alarm value(1)

10%LEL

Alarm method

Audio and visual alarming

Audio alarm sound

>=70dB

Sensor life

5 years

Application

Gas powered taxi and bus

Weight

  Appr. 270g

Note: (1) can be specified by the customer before the goods leaving the factory.

LED Indication:

Power LED: After electrifying, it will keep lighting, which means the detector is working.

Fault LED: If it is lighting, it means the detector is defective and without detecting function. Please contact the seller.

Alarm LED: When the detector gives alarming, it will light or flickers quickly until the gas concentration falls below the preset value.

Mute / Text Button:

This button is used to check the function of audio and video alarm. When there is no alarming signal, if push this button, fault and power LED lights are flickering and the buzzer gives sound. When the detector is giving alarming or in low voltage status, if push this button, audio alarm will be canceled. If either LED or buzzer is defective, please repair it in time, so as to avoid missing any alarm signal.

Wire Connection and Installation:

This alarm system is designed mainly for gas powered cars and buses use in the city.

For buses, the following is the installation position drawing:

(1) Rear engine (2)Gas bottle (3)Front engine (4) Rear area of the ceiling(5) Front area of the ceiling

If the bus is twin-layer, the quantity will be more.

Wire Connection and Installation

For taxies, the following is the installation position drawing: (1) Gas bottle (2) Engine

For taxies, the following is the installation position drawing

  

 