KAD Carbon Monoxide Alarm Comply with EN50291 standard |
| Brief Introduction: |
| KAD carbon monxide alarm, is designed to detect the concentration of carbon monoxide, adopts high-quality carbon monoxide sensor with advanced technology and superior craft. It provides visual and audible signals when the carbon monoxide concentration reaches the preset level. It reminds you to take prompt favorable action. |
| |
Main feautures: |
| |
Fuel Cell Sensor
LCD indicates gas concentration
Comply with standard EN50291
Peak value memory |
| |
Specifications: |
| |
Working power: 2AA battery (3V)
Display: LCD and back light
Working condition: Temperature: -10¡æ¡«55¡æ Humidity: <95%RH
Response time: ¡Ü30s
Gas sampling: Natural diffusion
Alarming method: Visual and audible
Alarm sound: ¡Ý85dB
Sensor life: >5 years
Weight: About: 420g
Dimension: L¡ÁW¡ÁH 170mm¡Á100mm¡Á45mm
Alarming level:
50ppm¡¡ Between 60-90mins
100ppm¡¡Between 10-40mins
300ppm¡¡Less than 3mins
 |
|